Logo

OpiCalc

FavoritesSpecialtiesDrugsGuidelinesMost Used

Quick Access

Favorites
Most Used

All Specialties

OpiCalc Logo
Clinical CalculatorsDrugsGuidelines
SpecsDrugsGuides
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
‌
OpiCalc Logo

OpiCalc

Easy, fast, and private medical tools for clinicians. Always free.

No Login Required
Ready for the Bedside

Resources

About UsEditorial PolicyMedical DisclaimerPrivacy PolicyTerms of UseCookie Policy

Support

Contact Us

Clinical Notice:OpiCalc is not a substitute for professional clinical judgment. Always verify dosages and guidelines.

OpiCalc © 2018-2026

•

All Rights Reserved

Registry Hub
Peer-Reviewed Evidence
HomeDrug RegistryCompareEVZIO AUTOINJECTOR vs RELISTOR
Comparative Pharmacology

EVZIO AUTOINJECTOR vs RELISTOR Comparison

Head-to-head clinical analysis & difference comparison: details on mechanism of action, dosing, half-life, interactions, and maternal-fetal safety.

Clinical EssentialsPharmacokineticsSpecial PopulationsSafety & MonitoringPregnancy & LactationClinical Insights
Differential Analysis

EVZIO (AUTOINJECTOR) vs RELISTOR

Clinician-reviewed, head-to-head comparison of mechanism, dosing, pharmacokinetics, and safety profiles.

View EVZIO (AUTOINJECTOR) Monograph View RELISTOR Monograph
EVZIO (AUTOINJECTOR)
Opioid Antagonist
Category C
RELISTOR
Peripheral Opioid Antagonist
Category C
TL;DR — Key Differences
  • Drug class: EVZIO (AUTOINJECTOR) is a Opioid Antagonist; RELISTOR is a Peripheral Opioid Antagonist.
  • Half-life: EVZIO (AUTOINJECTOR) has a half-life of Terminal elimination half-life of naloxone is approximately 1–2 hours in adults. The short half-life results in a duration of action that may be shorter than that of the opioid (e.g., fentanyl, methadone), necessitating repeated doses or continuous infusion. In neonates, half-life is prolonged (3–4 hours).; RELISTOR has Terminal elimination half-life is approximately 8-10 hours in patients with normal renal function. In patients with end-stage renal disease, half-life is prolonged (~14-18 hours)..
  • No direct drug-drug interaction has been documented between EVZIO (AUTOINJECTOR) and RELISTOR.
  • Pregnancy: EVZIO (AUTOINJECTOR) is rated Category C; RELISTOR is rated Category C.

Last clinically reviewed: July 2026 · OpiCalc Medical Review Team

Clinical Essentials

EVZIO (AUTOINJECTOR)
RELISTOR
Mechanism of Action
EVZIO (AUTOINJECTOR)

Competitive antagonist at mu-opioid receptors, reversing opioid-induced respiratory depression and other central nervous system depressant effects.

RELISTOR

Peripherally acting mu-opioid receptor antagonist that blocks opioid-induced constipation without affecting central analgesia.

Indications
EVZIO (AUTOINJECTOR)

Emergency treatment of known or suspected opioid overdose, manifested by respiratory and/or central nervous system depression

RELISTOR

Treatment of opioid-induced constipation (OIC) in adult patients with chronic non-cancer pain,Treatment of OIC in adult patients with advanced illness who are receiving palliative care

Standard Dosing
EVZIO (AUTOINJECTOR)

Adults: 2 mg intramuscularly or subcutaneously into the anterolateral thigh, repeat every 2-3 minutes as needed until emergency medical assistance arrives.

RELISTOR

0.15 mg/kg subcutaneously once daily, maximum 16 mg per dose; for opioid-induced constipation, 8 mg subcutaneously once daily.

Direct Interaction
EVZIO (AUTOINJECTOR)
No Direct Interaction
RELISTOR
No Direct Interaction

Pharmacokinetics

EVZIO (AUTOINJECTOR)
RELISTOR
Half-Life
EVZIO (AUTOINJECTOR)

Terminal elimination half-life of naloxone is approximately 1–2 hours in adults. The short half-life results in a duration of action that may be shorter than that of the opioid (e.g., fentanyl, methadone), necessitating repeated doses or continuous infusion. In neonates, half-life is prolonged (3–4 hours).

RELISTOR

Terminal elimination half-life is approximately 8-10 hours in patients with normal renal function. In patients with end-stage renal disease, half-life is prolonged (~14-18 hours).

Metabolism
EVZIO (AUTOINJECTOR)

Primarily hepatic via glucuronidation; minor pathways include N-dealkylation. CYP450 involvement is minimal.

RELISTOR

Primarily hepatic via CYP3A4 and CYP2D6 isoenzymes; also undergoes gut wall metabolism.

Excretion
EVZIO (AUTOINJECTOR)

Naloxone is primarily metabolized in the liver via glucuronidation, with minor contributions from N-dealkylation. The metabolites (naloxone-3-glucuronide) and parent drug are excreted renally. Approximately 50% of a dose is excreted in urine as naloxone-3-glucuronide, 25% as unchanged naloxone (after IV), and <5% in feces. Biliary excretion is minimal (<1%).

RELISTOR

Renal excretion of unchanged drug accounts for approximately 16% of the dose; biliary/fecal excretion is the major route (approximately 54% recovered in feces).

Protein Binding
EVZIO (AUTOINJECTOR)

Approximately 45% bound to plasma proteins, primarily albumin.

RELISTOR

Approximately 11-15% bound to plasma proteins (primarily albumin).

VD (L/kg)
EVZIO (AUTOINJECTOR)

2–3 L/kg in adults. The large Vd indicates extensive tissue distribution, including crossing the blood-brain barrier rapidly to reverse central opioid effects. In neonates, Vd is higher (3–5 L/kg).

RELISTOR

Approximately 1.1 L/kg (central volume ~0.3 L/kg); indicates extensive extravascular distribution.

Bioavailability
EVZIO (AUTOINJECTOR)

Intramuscular or subcutaneous: approximately 60–80% relative to IV (with the autoinjector delivering 0.4 mg or 2 mg doses). Oral bioavailability is <2% due to extensive first-pass metabolism, making oral administration ineffective for opioid reversal; thus, the autoinjector is for IM/SC use only.

RELISTOR

Subcutaneous: approximately 82-100% (mean ~97%); oral: approximately 6% (low due to first-pass metabolism).

Special Populations

EVZIO (AUTOINJECTOR)
RELISTOR
Renal Adjustments
EVZIO (AUTOINJECTOR)

No dose adjustment required for renal impairment.

RELISTOR

For creatinine clearance <30 m L/min: 0.075 mg/kg subcutaneously every other day, maximum 8 mg per dose; not recommended in patients with end-stage renal disease requiring dialysis.

Hepatic Adjustments
EVZIO (AUTOINJECTOR)

No dose adjustment required for hepatic impairment.

RELISTOR

No dose adjustment required for mild to moderate hepatic impairment (Child-Pugh A or B); not studied in severe impairment (Child-Pugh C).

Pediatric Dosing
EVZIO (AUTOINJECTOR)

Weight-based dosing: For children weighing <20 kg, 0.1 mg/kg intramuscularly or subcutaneously; for ≥20 kg, 2 mg intramuscularly or subcutaneously. Repeat every 2-3 minutes as needed.

RELISTOR

Safety and efficacy not established in pediatric patients.

Geriatric Dosing
EVZIO (AUTOINJECTOR)

No specific dose adjustment needed; use caution due to potential comorbidities.

RELISTOR

No specific dose adjustment recommended; use caution due to potential for renal impairment, monitor renal function.

Safety & Monitoring

EVZIO (AUTOINJECTOR)
RELISTOR
Black Box Warnings
EVZIO (AUTOINJECTOR)
FDA Black Box Warning

None.

RELISTOR
FDA Black Box Warning

Gastrointestinal perforation: Cases of gastrointestinal perforation have been reported in patients with conditions that may result in impaired structural integrity of the gastrointestinal tract.

Warnings/Precautions
EVZIO (AUTOINJECTOR)

Risk of acute withdrawal syndrome in opioid-dependent patients.,May precipitate severe withdrawal in neonates if used during pregnancy.,Limited efficacy against buprenorphine or partial agonists; higher or repeat doses may be needed.,Monitor for recurrence of respiratory depression due to short duration of action relative to some opioids.,Not a substitute for emergency medical care.

RELISTOR

Risk of gastrointestinal perforation,Opioid withdrawal symptoms including diarrhea, nausea, vomiting, abdominal pain,Disruption of analgesic effect if used with opioids crossing the blood-brain barrier (theoretical),Not recommended in patients with known or suspected mechanical gastrointestinal obstruction

Contraindications
EVZIO (AUTOINJECTOR)

Hypersensitivity to naloxone or any component of the autoinjector.

RELISTOR

Known or suspected mechanical gastrointestinal obstruction,Known hypersensitivity to methylnaltrexone or any component of the formulation

Adverse Reactions
EVZIO (AUTOINJECTOR)
Data Pending
RELISTOR
Data Pending
Food Interactions
EVZIO (AUTOINJECTOR)

No known food interactions with naloxone. No dietary restrictions required.

RELISTOR

No specific food interactions reported with methylnaltrexone. No dietary restrictions necessary. However, to optimize bowel function, patients should maintain adequate fluid intake and dietary fiber as tolerated, unless contraindicated due to underlying illness.

Pregnancy & Lactation

EVZIO (AUTOINJECTOR)
RELISTOR
Teratogenic Risk
EVZIO (AUTOINJECTOR)

Naloxone crosses the placenta. First trimester: No evidence of teratogenicity in animal studies at doses up to 100 mg/kg/day (SC). Second/third trimester: No known risk of fetal malformations; may precipitate withdrawal in opioid-dependent fetuses, potentially causing fetal distress or preterm labor.

RELISTOR

Animal studies show no teratogenic effects at doses up to 300 mg/kg/day in rats and rabbits. No adequate human data; risk cannot be excluded in first trimester. Second and third trimester: limited data, potential for gastrointestinal effects in fetus if exposed transplacentally.

Lactation Summary
EVZIO (AUTOINJECTOR)

Naloxone is excreted in breast milk in trace amounts; no adverse effects reported in nursing infants. M/P ratio not available.

RELISTOR

Excreted in human milk at low concentrations; M/P ratio approximately 0.6. No reported adverse effects in breastfeeding infants. Caution advised due to potential for gastrointestinal effects.

Pregnancy Dosing
EVZIO (AUTOINJECTOR)

No pharmacokinetic data indicate dose adjustments; use same dose as non-pregnant adults. Reversal of opioid effects may precipitate withdrawal; monitor closely.

RELISTOR

No pharmacokinetic studies in pregnancy; dose adjustments not recommended based on available data. Use only if clearly needed for severe opioid-induced constipation unresponsive to standard therapy.

Maternal Safety Status
EVZIO (AUTOINJECTOR)
Category C
RELISTOR
Category C

Clinical Insights

EVZIO (AUTOINJECTOR)
RELISTOR
Clinical Pearls
EVZIO (AUTOINJECTOR)

EVZIO is a naloxone auto-injector for emergency treatment of opioid overdose. Administer intramuscularly or subcutaneously into anterolateral thigh (through clothing if necessary). Each device delivers a single 2 mg dose. After use, seek immediate medical attention due to short half-life (30-81 min) relative to opioids; repeated doses may be needed. Monitor for opioid withdrawal syndrome, especially in physically dependent patients. Store at 20-25°C (68-77°F), excursions permitted to 15-30°C (59-86°F). Do not remove the auto-injector from its case until ready to use.

RELISTOR

Relistor (methylnaltrexone) is a peripherally acting mu-opioid receptor antagonist (PAMORA) used for opioid-induced constipation (OIC) in patients with advanced illness or chronic pain. It does not cross the blood-brain barrier, thus does not reverse central opioid analgesia. Administer subcutaneously; onset typically within 1-4 hours. Contraindicated in patients with known or suspected mechanical gastrointestinal obstruction. Use with caution in renal impairment (Cr Cl <30 m L/min) as dose reduction recommended. Monitor for gastrointestinal perforation, especially in patients with underlying GI pathology. Coadministration with other opioid antagonists may precipitate opioid withdrawal.

Patient Counseling
EVZIO (AUTOINJECTOR)

Inject EVZIO into the outer thigh, through clothing if needed, as soon as overdose is suspected.,After injecting, call 911 or seek emergency medical help immediately.,The effect of EVZIO lasts only 30-90 minutes; opioids may last longer, so repeated doses might be necessary.,Family and caregivers should receive training on recognizing overdose signs (unconsciousness, slow breathing, pinpoint pupils) and using EVZIO.,Store EVZIO in its case at room temperature, away from light and moisture; do not refrigerate or freeze.,Check expiration date regularly and replace before expiry; training devices are for practice only.,An overdose may cause withdrawal symptoms such as nausea, vomiting, sweating, rapid heart rate, or agitation.

RELISTOR

Relistor is used to treat constipation caused by opioid pain medications without affecting pain relief.,Inject the medication exactly as prescribed; do not use more often than every other day.,You should have a bowel movement within a few hours of receiving the injection; if not, contact your doctor.,Common side effects include abdominal pain, nausea, diarrhea, and flatulence.,Stop Relistor and seek immediate medical attention if you experience severe abdominal pain, vomiting, or signs of intestinal obstruction (e.g., inability to pass gas).,Tell your doctor if you have kidney problems, as the dose may need adjustment.,Do not take other medicines for constipation without your doctor's approval.

Safety Verification

Known Interactions

EVZIO (AUTOINJECTOR) Risks

No interactions on record

RELISTOR Risks

No interactions on record

Compare Alternatives

Related Drug Comparisons

Explore head-to-head clinical comparisons of other medications in the same therapeutic classes.

EVZIO (AUTOINJECTOR) vs BUPRENORPHINE HYDROCHLORIDE AND NALOXONE HYDROCHLORIDEOpioid Antagonist
RELISTOR vs BUPRENORPHINE HYDROCHLORIDE AND NALOXONE HYDROCHLORIDEOpioid Antagonist
EVZIO (AUTOINJECTOR) vs BUPRENORPHINE HYDROCHLORIDE; NALOXONE HYDROCHLORIDEOpioid Antagonist
RELISTOR vs BUPRENORPHINE HYDROCHLORIDE; NALOXONE HYDROCHLORIDEOpioid Antagonist
EVZIO (AUTOINJECTOR) vs ENTEREGPeripheral Opioid Antagonist
RELISTOR vs ENTEREGPeripheral Opioid Antagonist
EVZIO (AUTOINJECTOR) vs EVZIOOpioid Antagonist
RELISTOR vs EVZIOOpioid Antagonist
EVZIO (AUTOINJECTOR) vs KLOXXADOOpioid Antagonist
Clinical Q&A

Frequently Asked Questions

Common clinical questions about EVZIO (AUTOINJECTOR) vs RELISTOR, answered by our medical review team.

1. What is the main difference between EVZIO (AUTOINJECTOR) and RELISTOR?

EVZIO (AUTOINJECTOR) is a Opioid Antagonist that works by Competitive antagonist at mu-opioid receptors, reversing opioid-induced respiratory depression and other central nervous system depressant effects.. RELISTOR is a Peripheral Opioid Antagonist that works by Peripherally acting mu-opioid receptor antagonist that blocks opioid-induced constipation without affecting central analgesia.. They differ in pharmacokinetic profiles, FDA-approved indications, and side effect profiles.

2. Which is stronger: EVZIO (AUTOINJECTOR) or RELISTOR?

Potency comparisons between EVZIO (AUTOINJECTOR) and RELISTOR depend on the specific clinical indication. These are agents from distinct pharmacological classes and are not directly interchangeable by dose. A physician or clinical pharmacist should guide any therapeutic switching decisions.

3. What is the standard dosing for EVZIO (AUTOINJECTOR) vs RELISTOR?

The standard adult dose of EVZIO (AUTOINJECTOR) is: Adults: 2 mg intramuscularly or subcutaneously into the anterolateral thigh, repeat every 2-3 minutes as needed until emergency medical assistance arrives.. The standard adult dose of RELISTOR is: 0.15 mg/kg subcutaneously once daily, maximum 16 mg per dose; for opioid-induced constipation, 8 mg subcutaneously once daily.. Dosing should always be individualized based on indication, renal and hepatic function, age, and other patient factors.

4. Can you take EVZIO (AUTOINJECTOR) and RELISTOR together?

No direct drug-drug interaction has been formally documented between EVZIO (AUTOINJECTOR) and RELISTOR in current clinical databases. However, individual patient risk factors including other medications, organ function, and comorbidities should always be evaluated by a qualified healthcare provider.

5. Are EVZIO (AUTOINJECTOR) and RELISTOR safe during pregnancy?

The maternal-fetal safety profiles differ. EVZIO (AUTOINJECTOR) is classified as Category C. Naloxone crosses the placenta. First trimester: No evidence of teratogenicity in animal studies at doses up to 100 mg/kg/day (SC). Second/third trimester: No known risk of fetal ma. RELISTOR is classified as Category C. Animal studies show no teratogenic effects at doses up to 300 mg/kg/day in rats and rabbits. No adequate human data; risk cannot be excluded in first trimester. Second and third tr. Always consult a maternal-fetal medicine specialist before taking either drug during pregnancy or lactation.